Rockwell-automation 2098-DSD-xxx Ultra3000 Host Commands for Serial In Instrukcja Użytkownika Strona 29

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 176
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 28
Publication 2098-RM003A-EN-P October 2001
Command Reference 2-13
Setpoint Velocity
Setpoint Acceleration
Reset Faults
Format: :aa06Dfddddddddcc<cr>
Parameter
Code:
0x06D
Valid Function
Codes:
0x0 = Read Working Value
0x1 = Write Working Value
0x8 = Read Minimum Value
0x9 = Read Maximum Value
Valid Exception
Codes:
0x04 = Data Below Minimum
0x08 = Invalid Function Code
Data Fields: dddddddd Setpoint velocity, in units of counts/second.
Minimum
Value:
0x80000001
Maximum
Value:
0x7FFFFFFF
Default: 0x0000
Format: :aa06Efddddddddcc<cr>
Parameter
Code:
0x06E
Valid Function
Codes:
0x0 = Read Working Value
0x1 = Write Working Value
0x8 = Read Minimum Value
0x9 = Read Maximum Value
Valid Exception
Codes:
0x05 = Data Above Maximum
0x08 = Invalid Function Code
Data Fields: dddddddd Setpoint acceleration, in units of counts/sec/sec.
Minimum
Value:
0x00000000
Maximum
Value:
0x7FFFFFFF
Default: 100,000
Format: :aa06Ffcc<cr>
Parameter
Code:
0x06F
Valid Function
Codes:
0x1 = Write Working Value
Valid Exception
Codes:
0x08 = Invalid Function Code
Data Fields: None
Przeglądanie stron 28
1 2 ... 24 25 26 27 28 29 30 31 32 33 34 ... 175 176

Komentarze do niniejszej Instrukcji

Brak uwag