190 Rockwell Automation Publication 280E-UM001B-EN-P – July 2012
Chapter 7 Bulletin 280E/281E/284E Programmable Parameters
Figure 74 - EM Brk OFF Delay
StpLogic Time 0 (250)
StpLogic Time 1 (251)
StpLogic Time 2 (252)
StpLogic Time 3 (253)
StpLogic Time 4 (254)
StpLogic Time 5 (255)
StpLogic Time 6 (256)
StpLogic Time 7 (257)
Sets the time to remain in each step if
the corresponding Parameter 138
(Speed Reference) is set to “6”
(StpLogic), Parameter 240-247
(StpLogic x), digits 0…3 set to b, C, d
or E (Step after (StpLogic Time x).
Parameter Number 250…257
Related Parameters 138, 155, 171…177, 240…247
Access Rule GET/SET
Data Type UINT
Group Drive Advanced Setup
Units 0.1 sec
Minimum Value 0.0 sec
Maximum Value 999.9 sec
Default Value 30.0 sec
EM Brk OFF Delay
Sets the time the drive will remain at
minimum frequency before ramping
to the commanded frequency and
energizing the brake coil relay when
Parameter 137 (Stop Mode) is set to
Option 8 or 9.
Parameter Number 260
Related Parameters 134, 137
Access Rule GET/SET
Data Type UNIT
Group Drive Advanced Setup
Units 0.01 sec
Minimum Value 0.01 sec
Maximum Value 10 sec
Default Value 0.0 sec
Frequency
Time
Minimum Freq
260 [EM Brk O Delay]
261 [EM Brk On Delay]
Stop
Commanded
Start
Commanded
EM Brk
De-Energized (On)
Drive StopsEM Brk
Energized (O)
Ramp Accel
Ramp Decel