294 Rockwell Automation Publication 280E-UM001B-EN-P – July 2012
Appendix B CIP Information
115 Get Warning Status WORD
Bits 0…1 = Reserved
Bit 2 = PL Warning (does not apply for Ethernet version)
Bit 3 = Reserved
Bit 4 = PR Warning (does not apply for Ethernet version)
Bit 5 = CP Warning
Bit 6 = I/O Warning
Bit 7 = Reserved
Bit 8 = PI Warning (does not apply for Ethernet version)
Bit 9 = DN Warning
Bits 10…12 = Reserved
Bit 13 = HW Warning
Bits 14…15 = Reserved
124 Get/Set Trip Enable WORD Bit enumerated trip enable word
130 Get/Set Trip Reset Mode BOOL 0 = Manual, 1 = Auto
131 Get/Set Trip Reset Level USINT 0 = 100%, Default = 75
150
Get/Set High Speed Ena BOOL 0 = Disable, 1 = Enable
151 Get Base Enclosure WORD
Bit 0 = IP67
Bit 1 = NEMA 4x
Bits 2…15 Reserved
152 Get Base Options WORD
Bit 0 = Output Fuse
Bit 1 = Safety Monitor
Bit 2 = CP Fuse Detect
Bits 3…7 = Reserved
Bit 8 = 10A Base
Bit 9 = 25A Base
Bit 10…15 = Reserved
153 Get Wiring Options WORD
Bit 0 = Conduit
Bit 1 = Round Media
Bits 2…15 = Reserved
Attribute ID Access Rule Name Data Type Value