Rockwell Automation Publication 2098-UM001G-EN-P - February 2011 115
Configuring the Ultra3000 Drive Chapter 3
Idle Fault Action Determines the action the drive should take if the master sends
a zero length I/O message to the drive, that may occur if a PLC
(master) is set to program mode. The options are:
Fault / Zero Data
Fault / Hold Last Data
Zero Data
Hold Last Data
Fault Configuration
Note: Refer to the Ultra3000 DSD with DeviceNet Reference
Manual, publication 2098-RM001 for information on these
options.
Comm Fault Action Determines the action the drive should take if the drive detects
a network failure while an I/O messaging connection is active.
The options are:
Fault / Zero Data
Fault / Hold Last Data
Zero Data
Hold Last Data
Fault Configuration
Note: Refer to the Ultra3000 DSD with DeviceNet Reference
Manual, publication 2098-RM001 for information on these
options.
Faulted Logic Command Provides the logic command data to the drive when the drive
receives an invalid I/O message or detects a network failure
while an I/O messaging connection is active. Desired options
include:
Define Home
Define Position
Disable Serial Communications
Drive Enable
Fault Reset
Follower Enable
Integrator Inhibit
Operation Mode Override
Pause Homing
Pause Index
Position Strobe
Preset Select 0
Preset Select 1
Preset Select 2
Preset Select 3
Preset Select 4
Preset Select 5
Remove Command Offset
Reset Drive
Start Homing
Stop Indexing
Stop Homing
Start Indexing
Parameter Description
Przeglądanie stron 112