Chapter 5 Configuring the Kinetix 3 Drive
You can edit Analog parameters for both an online and an offline drive. However,
you can monitor status, and execute direct commands (executed through the
Ultraware interface) only for a Analog window that is the child of an online drive.
The following status is displayed by default for an Analog window of an online
drive.
The following commands can be executed for an Analog window that is in the
On-Line Drives branch.
Customize the Analog window for your Kinetix 3 drive by selecting one or more
of these commands:
• Click Show Status to display or hide the Status pane.
• Click Show Commands to display or hide the Commands pane.
• Click Setup to open the Monitor Setup window as shown on page 275
,
where you can customize the status display for this window.
• Click Revert to return parameter settings to the values they held when you
opened this window.
Status Description
Analog Command Velocity The voltage at the Analog Velocity command input.
Analog Command Current The voltage at the Analog Current command input.
Command Velocity The commanded velocity
Command Current The commanded current
Command Description
Remove Velocity Input Offset This command automatically measures the existing offset of the
Analog Command Input, and resets the Velocity Offset value to
eliminate the offset.
Remove Current Input Offset This command automatically measures the existing offset of the
Analog Command Input, and resets the Current Offset value to
eliminate the offset.
Save Parameters Saves the current working values as power-up values in the
flash memory for the selected On-Line drive and all of its
children.