196 Rockwell Automation Publication 2098-UM001G-EN-P - February 2011
Chapter 4 Configuring the Ultra5000 Drive
Monitoring Your Ultra5000
Drive
The Monitor tool lets you display all or any combination of drive status settings
for a selected Ultra5000 online drive. The Monitor tool works just like the status
pane of a branch’s Properties window.
Use this window to:
• Display the status settings that have been selected for display in the
Monitor Setup window.
• Open the Monitor Setup window, in which you can display the drive
status.
This window has these commands.
To monitor your drives, perform these steps.
1. Double-click the Monitor icon in the Workspace window. The Monitor
window appears in the Client Area.
2. Click Setup to open the Monitor Setup window as shown on page 197
.
You can customize the display of the Monitor window for the selected
online Ultra5000 drive. The window displays a tree diagram with all the
status settings that can be monitored for the selected drive.
Refer to
Ultra5000 Status on page 199 for a detailed list of drive status
selections.
Command Description
Format The format for displaying integer values in the monitor:
• Decimal
• Binary
• Hexadecimal
Load Opens the Monitor Load dialog box, where you can:
• Load a previously saved monitor from the list.
• Delete an existing monitor from the list.
• Save as default an existing monitor to automatically load
each time you open the Monitor window.
Save Opens the Monitor Save dialog box, where you can:
• Save a monitor, under a new or existing name, for later use.
• Delete an existing monitor from the list.
• Save as default an existing monitor to automatically load
each time you open the Monitor window.
Reset Peaks Resets peak value parameters to zero. For example, Position
Error Peak -, Position Error Peak +, Current Peak -, Current Peak
+.
Setup Opens the Monitor Setup window, where you can display the
drive status.
Refer to
Ultra5000 Status on page 199 for a detailed list of drive
status selections.