Rockwell Automation Publication 2098-UM001G-EN-P - February 2011 69
Configuring the Ultra3000 Drive Chapter 3
This command can be executed from a Indexing window of an online drive:
Customize the Indexing window for your Ultra3000 Drive by selecting one or
more of these commands:
Click Show Status to display or hide the Status pane.
Click Show Commands to display or hide the Commands pane.
Click Setup to open the Monitor Setup window as shown on page 105
,
where you can customize the status display for this window.
Click Revert to return parameter settings to the values they held when you
opened this window.
In Position ON indicates the position error has been less than the In
Position Window Size setting for longer than the In Position
Window Time setting, and the speed is less than the Zero Speed
setting, as configured in the Ultra3000 Drive window.
Note: The In Position status has a value of 1 when ON, and 0
when OFF.
Position Command The motor’s commanded position, relative to the Home position
of zero.
Actual Position The motor’s actual position, relative to the Home position of
zero.
Command Description
Index Control Panel Opens the Indexing Control Panel window.
Status Description