Rockwell Automation Publication 2071-RM001B-EN-P - April 2013 107
Standard Drive Parameters Appendix A
Range 0 = Disabled
1 = Enabled
When Enabled Servo-Off -> Setting -> After power cycle
Applicable Operating Mode All
[Pr - 9.21] Motor Thermal Resistance, Winding to Encoder
Ultraware Name Thermal: Rth (w-e)
Range 1…2,147,483,647
Units °C/Watt * 65,536
When Enabled Servo-Off -> Setting -> After power cycle
Applicable Operating Mode All
[Pr - 9.22] Motor Thermal Capacitance, Winding to Encoder
Ultraware Name Thermal: Cth (w-e)
Range 1…2,147,483,647
Units J/°C *256
When Enabled Servo-Off -> Setting -> After power cycle
Applicable Operating Mode All
[Pr - 9.23] Motor Thermal Resistance, Winding to Ambient
Ultraware Name Thermal: Rth (w-a)
Range 1…2,147,483,647
Units °C/Watt * 65,536
When Enabled Servo-Off -> Setting -> After power cycle
Applicable Operating Mode All
[Pr - 9.24] Motor Thermal Capacitance, Winding to Ambient
Ultraware Name Thermal: Cth (w-a)
Range 1…2,147,483,647
Units J/°C *256
When Enabled Servo-Off -> Setting -> After power cycle
Applicable Operating Mode All
[Pr - 9.25] Commutation Type
Ultraware Name Feedback: Commutation
[Pr - 9.20] Motor Thermostat