118 Rockwell Automation Publication 2071-RM001B-EN-P - April 2013
Appendix B Indexing Drive Parameters
[IN01.01] Auto Start Homing on Enable
Ultraware Name Auto Start Homing on Enable
Description Causes the drive to begin the homing procedure
automatically when the drive is enabled.
Range Value Description
0 Active: Automatically starts
homing every time the
drive is enabled.
1 Active After Reset Only:
automatically starts
homing when a drive is
enabled, if the drive has
not already been homed.
2 Inactive
Default 2
Units N/A
Access Set
Changeable Status Always
When Enabled Power cycling
Applicable Operating Mode Indexing
Modbus Address 5201
[IN01.02] Homing Velocity
Ultraware Name Homing Velocity
Description The commanded velocity used during homing. The sign of
the this value (+/-) indicates the direction of motion
during homing.
Range Value Description
-6000 …6000 Rotary motors: rpm;
Linear motors: mm/s
Default 100
Access Set
Changeable Status Disable Drive
When Enabled Disable Drive
Applicable Operating Mode Indexing
Modbus Address 5202