Appendix D Monitor Variables
Variable 26 - Digital Outputs
Digital output status is provided by Variable 26 - Digital Outputs. Digital inputs
and outputs [Pr - 0.02]
, and [Pr - 0.22][Pr - 0.24] are compiled for this variable.
The table below lists the data bits in this variable.
Variable 29 - Indexing Inputs
Indexing input function status is provided by Variable 29 - Indexing Inputs.
Digital inputs [Pr - 0.16]
[Pr - 0.18] are compiled for this variable.
The table below lists the data bits in this variable.
Bit Digital Output Function
0Brake
1 Absolute Position Valid
2Current Limited
3 Velocity Limited
4 Within Near Window
5 Warning: Absolute Encoder Battery
6 Warning: Absolute Encoder Count Overflow
7Warning: Power Up Overspeed
8 Warning: Over Current Command
9 Warning: Over Speed Command
10 Warning: Digital IO Assignment
11 Warning: Over Motor Rated Power
Bit Indexing Input function
0 Home Sensor
1 Start Homing
2 Start Indexing
3 Stop Indexing
4 Pause Index
5 Index Select 0 Input
6 Index Select 1 Input
7 Index Select 2 Input
8 Index Select 3 Input
9 Index Select 4 Input
10 Index Select 5 Input
11 Stop Homing