Rockwell-automation 2071-Axx Kinetix 3 Component Servo Drive Serial Ho Instrukcja Użytkownika Strona 122

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 146
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 121
122 Rockwell Automation Publication 2071-RM001B-EN-P - April 2013
Appendix B Indexing Drive Parameters
[IN01.09] Home Current
Ultraware Name Home Current
Description Specifies the torque feedback at which the drive stops
moving the motor at the Homing Velocity.
Range Value Description
1 …250 Percent of motor torque
feedback
Default 100
Units Percentage of a motor rating torque
Access Set
Changeable Status Disable Drive
When Enabled Disable Drive
Applicable Operating Mode Indexing
Modbus Address 5213
[IN01.10] Home Current Time
Ultraware Name Home Current Time
Description Specifies the time interval that the home current must be
held.
Range Value Description
0 …1000 ms
Default 0
Units Milliseconds
Access Set
Changeable Status Disable Drive
When Enabled Disable Drive
Applicable Operating Mode Indexing
Modbus Address 5214
Przeglądanie stron 121
1 2 ... 117 118 119 120 121 122 123 124 125 126 127 ... 145 146

Komentarze do niniejszej Instrukcji

Brak uwag